Needles for Willcox & Gibbs Sewing Machines - All Models
Needles for Willcox & Gibbs Sewing Machines - All Models
Please Note
- Older machines sometimes get retrofitted with needle bars that handle use different needle systems from the original design.
- There are occasionally instances where the needle point, needle size, or both affect the needle system designation. The most common exceptions occur with DBx1, 134, 1738A, 135x16. and 135x17. Details
Select Model Range
Willcox & Gibbs Model# 4 All Classes with exceptions use needle system UY 121 GS Equivalent to 62x21, DVX1, MY 1001, CANU 36:05
Willcox & Gibbs Model# 4-350 uses needle system UY 113 GS Equivalent to 2055, UOX113 GS, CANU 26:65
Willcox & Gibbs Model# 4-480 uses needle system UY 128 GAS Equivalent to 149X3, 1280, TVX3, CANU 38:00
Willcox & Gibbs Model# 4-870 uses needle system UY 113 GS Equivalent to 2055, UOX113 GS, CANU 26:65
Willcox & Gibbs Model# 4-885 uses needle system UY 113 GS Equivalent to 2055, UOX113 GS, CANU 26:65
Willcox & Gibbs Model# 21 uses needle system UY 128 GAS Equivalent to 149X3, 1280, TVX3, CANU 38:00
Willcox & Gibbs Model# 32 to 33 uses needle system 443 W, CANU 04:14 - Reference Only - Not Carried
Willcox & Gibbs Model# 41 All Classes use needle system UY 128 GAS Equivalent to 149X3, 1280, TVX3, CANU 38:00
Willcox & Gibbs Model# 42 All Classes use needle system UY 128 GAS Equivalent to 149X3, 1280, TVX3, CANU 38:00
Willcox & Gibbs Model# 43 All Classes use needle system UY 128 GAS Equivalent to 149X3, 1280, TVX3, CANU 38:00
Willcox & Gibbs Model# 61 to 63 uses needle system UY 128 GAS Equivalent to 149X3, 1280, TVX3, CANU 38:00
Willcox & Gibbs Model# 101 to 102 uses needle system 1738A Equivalent to 16x95, 16X231, 71x1, 287 WH, CANU 14:25
Willcox & Gibbs Model# 300 All Classes use needle system 561-1 Equivalent to 555, 561/1, 2019, FLX555, CANU 23:45
Willcox & Gibbs Model# 300 All Classes use needle system 561-2 Equivalent to 551, 555, 555 A, 561/2, 2020, FLX1A, FLX2A, CANU 23:46
Willcox & Gibbs Model# 301-P METROPOLITAN uses needle system 62X43 Equivalent to DVX43, CANU 38:10
Willcox & Gibbs Model# 400 uses needle system 443 W, CANU 04:14 - Reference Only - Not Carried
Willcox & Gibbs Model# 401 All Classes with exceptions use needle system B 27 Equivalent to 81x1, DCx27, DCx1, MY 1023, UY 191 GS, CANU 03:36
Willcox & Gibbs Model# 401 - uses needle system DMX13 Equivalent to 82X13, 1886 KK, CANU 03:28
Willcox & Gibbs Model# 500 All Classes EXEPT uses needle system UY 154 GAS Equivalent to 151x21, UY 154 GAS SES, UY 154 FGS, UYX15, CANU 06:60EB
Willcox & Gibbs Model# 500-IV uses needle system B 27 Equivalent to 81x1, DCx27, DCx1, MY 1023, UY 191 GS, CANU 03:36
Willcox & Gibbs Model# 502 uses needle system 64 Equivalent to SOBAR, W&Gx64, W&G 502, WY 502, CANU 02:50
Willcox & Gibbs Model# 502 uses needle system 501 SC Equivalent to 1807 (D), 755 H, EBX755, CANU 08:28
Willcox & Gibbs Model# 503 All Classes EXEPT uses needle system UY 154 GAS Equivalent to 151x21, UY 154 GAS SES, UY 154 FGS, UYX15, CANU 06:60EB
Willcox & Gibbs Model# 503-E 52 -211 uses needle system B 27 Equivalent to 81x1, DCx27, DCx1, MY 1023, UY 191 GS, CANU 03:36
Willcox & Gibbs Model# 504 4 All Classes use needle system B 27 Equivalent to 81x1, DCx27, DCx1, MY 1023, UY 191 GS, CANU 03:36
Willcox & Gibbs Model# 504-1-45 uses needle system UY 154 GAS Equivalent to 151x21, UY 154 GAS SES, UY 154 FGS, UYX15, CANU 06:60EB
Willcox & Gibbs Model# 504-E All Classes use needle system UY 154 GAS Equivalent to 151x21, UY 154 GAS SES, UY 154 FGS, UYX15, CANU 06:60EB
Willcox & Gibbs Model# 504-I All Classes use needle system UY 154 GAS Equivalent to 151x21, UY 154 GAS SES, UY 154 FGS, UYX15, CANU 06:60EB
Willcox & Gibbs Model# 504-II All Classes use needle system UY 154 GAS Equivalent to 151x21, UY 154 GAS SES, UY 154 FGS, UYX15, CANU 06:60EB
Willcox & Gibbs Model# 504-V uses needle system UY 154 GAS Equivalent to 151x21, UY 154 GAS SES, UY 154 FGS, UYX15, CANU 06:60EB
Willcox & Gibbs Model# 512 All Classes with exceptions use needle system B 27 Equivalent to 81x1, DCx27, DCx1, MY 1023, UY 191 GS, CANU 03:36
Willcox & Gibbs Model# 512-II uses needle system UY 8454 GS Equivalent to UY 8454 GAS, UY 8454 GAS SES,UNX, CANU 06:62EB
Willcox & Gibbs Model# 514 All Classes with exceptions use needle system B 27 Equivalent to 81x1, DCx27, DCx1, MY 1023, UY 191 GS, CANU 03:36
Willcox & Gibbs Model# 514-I to 414 II uses needle system UY 8454 GS Equivalent to UY 8454 GAS, UY 8454 GAS SES,UNX, CANU 06:62EB
Willcox & Gibbs Model# 515 to 516 uses needle system B 27 Equivalent to 81x1, DCx27, DCx1, MY 1023, UY 191 GS, CANU 03:36
Willcox & Gibbs Model# 521 uses needle system UY 154 GBS Equivalent to UY 154 GCS, UYX154 GCS, CANU 06:66EB
Willcox & Gibbs Model# 802 to 803 uses needle system UY 162 GBS Equivalent to 576, CANU 05:63
Willcox & Gibbs Model# 810 to 813 uses needle system UY 162 GBS Equivalent to 576, CANU 05:63
Willcox & Gibbs Model# 822 to 823 uses needle system UY 162 GBS Equivalent to 576, CANU 05:63
Willcox & Gibbs Model# 900 uses needle system B 63 Equivalent to DVX63, CANU 35:40
Willcox & Gibbs Model# 928 uses needle system B 63 Equivalent to DVX63, CANU 35:40
Willcox & Gibbs Model# 930 All Classes use needle system UY 143 GS Equivalent to 92x1, DNX1, MY 1013, UOX143 G, CANU 45:30
Willcox & Gibbs Model# 950 All Classes use needle system B 63 Equivalent to DVX63, CANU 35:40
Willcox & Gibbs Model# 951 - uses needle system B 63 Equivalent to DVX63, CANU 35:40
Willcox & Gibbs Model# 958 uses needle system B 63 Equivalent to DVX63, CANU 35:40
Willcox & Gibbs Model# 961-METROPOLITAN uses needle system B 63 Equivalent to DVX63, CANU 35:40
Willcox & Gibbs Model# 970-METROPOLITAN uses needle system B 63 Equivalent to DVX63, CANU 35:40
Willcox & Gibbs Model# 980 uses needle system B 63 Equivalent to DVX63, CANU 35:40
Willcox & Gibbs Model# 990 All Classes with exceptions use needle system B 63 Equivalent to DVX63, CANU 35:40
Willcox & Gibbs Model# 990-METROPOLITAN M uses needle system UY 113 GS Equivalent to 2055 ,UOX113, CANU 26:25
Willcox & Gibbs Model# 992 All Classes use needle system UY 113 GS Equivalent to 2055 ,UOX113, CANU 26:25
Willcox & Gibbs Model# 994 All Classes use needle system UY 113 GS Equivalent to 2055 ,UOX113, CANU 26:25
Willcox & Gibbs Model# 996 uses needle system B 63 Equivalent to DVX63, CANU 35:40
Willcox & Gibbs Model# 996-METROPOLITAN M uses needle system UY 113 GS Equivalent to 2055 ,UOX113, CANU 26:25
Willcox & Gibbs Model# 998 uses needle system B 63 Equivalent to DVX63, CANU 35:40
Willcox & Gibbs Model# 998-METROPOLITAN M uses needle system UY 113 GS Equivalent to 2055 ,UOX113, CANU 26:25
Willcox & Gibbs Model# 1310 to 1311 uses needle system 561-1 Equivalent to 555, 561/1, 2019, FLX555, CANU 23:45
Willcox & Gibbs Model# 1310 to 1311 uses needle system 561-2 Equivalent to 551, 555, 555 A, 561/2, 2020, FLX1A, FLX2A, CANU 23:46
Willcox & Gibbs Model# 1400 uses needle system UY 162 GBS Equivalent to 576, CANU 05:63
Willcox & Gibbs Model# 1402 uses needle system UY 162 GBS Equivalent to 576, CANU 05:63
Willcox & Gibbs Model# 1410 uses needle system UY 162 GBS Equivalent to 576, CANU 05:63
Willcox & Gibbs Model# 1412 All Classes use needle system UY 162 GBS Equivalent to 576, CANU 05:63
Willcox & Gibbs Model# 1420 uses needle system UY 162 GBS Equivalent to 576, CANU 05:63
Willcox & Gibbs Model# 1422 uses needle system UY 162 GBS Equivalent to 576, CANU 05:63
Willcox & Gibbs Model# 1500 uses needle system UY 113 GS Equivalent to 2055 ,UOX113, CANU 26:25
Willcox & Gibbs Model# 1502 uses needle system UY 113 GS Equivalent to 2055 ,UOX113, CANU 26:25
Willcox & Gibbs Model# 1504 uses needle system UY 113 GS Equivalent to 2055 ,UOX113, CANU 26:25
Willcox & Gibbs Model# 1522 uses needle system UY 113 GS Equivalent to 2055 ,UOX113, CANU 26:25
Willcox & Gibbs Model# 1524 uses needle system UY 113 GS Equivalent to 2055 ,UOX113, CANU 26:25
Willcox & Gibbs Model# 1600 to 1603 uses needle system B 63 Equivalent to DVX63, CANU 35:40
Willcox & Gibbs Model# 1612 uses needle system B 63 Equivalent to DVX63, CANU 35:40
Willcox & Gibbs Model# 4530 uses needle system UY 113 GS Equivalent to 2055, UOX113 GS, CANU 26:65
Willcox & Gibbs Model# 5463 All Classes use needle system 4463 KK Equivalent to UOX4463, CANU 18:63
Willcox & Gibbs Model# 5467-801 uses needle system 4463 KK Equivalent to UOX4463, CANU 18:63
Willcox & Gibbs Model# BS-300 uses needle system 2091 Equivalent to 29 LES, 175X7, TQX7, CANU 47:42JB
Willcox & Gibbs Model# DC uses needle system B 27 Equivalent to 81x1, DCx27, DCx1, MY 1023, UY 191 GS, CANU 03:36
Willcox & Gibbs Model# DCM All Classes with exceptions use needle system 81X1 Equivalent to 82X1, DCX1, DMX1, CANU 03:33
Willcox & Gibbs Model# DCM - uses needle system B 27 Equivalent to 81x1, DCx27, DCx1, MY 1023, UY 191 GS, CANU 03:36
Willcox & Gibbs Model# DCMS All Classes with exceptions use needle system 81X1 Equivalent to 82X1, DCX1, DMX1, CANU 03:33
Willcox & Gibbs Model# DCMS - uses needle system B 27 Equivalent to 81x1, DCx27, DCx1, MY 1023, UY 191 GS, CANU 03:36
Willcox & Gibbs Model# DCP uses needle system B 27 Equivalent to 81x1, DCx27, DCx1, MY 1023, UY 191 GS, CANU 03:36
Willcox & Gibbs Model# DCP-101 uses needle system 81X1 Equivalent to 82X1, DCX1, DMX1, CANU 03:33
Willcox & Gibbs Model# DCP-103 uses needle system 81X1 Equivalent to 82X1, DCX1, DMX1, CANU 03:33
Willcox & Gibbs Model# DCR-942 uses needle system 81X1 Equivalent to 82X1, DCX1, DMX1, CANU 03:33
Willcox & Gibbs Model# DH uses needle system 24X1 Equivalent to DHX1, CANU 02:65
Willcox & Gibbs Model# DM All Classes with exceptions use needle system 81X1 Equivalent to 82X1, DCX1, DMX1, CANU 03:33
Willcox & Gibbs Model# DM - uses needle system DMX13 Equivalent to 82X13, 1886 KK, CANU 03:28
Willcox & Gibbs Model# DTN-1-8 NEEDLES uses needle system UY 113 GS Equivalent to 2055, UOX113 GS, CANU 26:65
Willcox & Gibbs Model# DTN-9 NEEDLES AND ABOVE uses needle system 62X57 Equivalent to 5640, DVX57, SY 3260, CANU 33:30
Willcox & Gibbs Model# DVM All Classes use needle system UY 121 GS Equivalent to 62x21, DVX1, MY 1001, CANU 36:05
Willcox & Gibbs Model# DWM All Classes use needle system UY 121 GS Equivalent to 62x21, DVX1, MY 1001, CANU 36:05
Willcox & Gibbs Model# E All Classes with exceptions use needle system B 27 Equivalent to 81x1, DCx27, DCx1, MY 1023, UY 191 GS, CANU 03:36
Willcox & Gibbs Model# E-56 to E 57 uses needle system UY 154 GAS Equivalent to 151x21, UY 154 GAS SES, UY 154 FGS, UYX15, CANU 06:60EB
Willcox & Gibbs Model# FS-601 uses needle system UY 118 GAS Equivalent to FLx118, FLX118 A, CANU 24:08
Willcox & Gibbs Model# R 57-L14 57 uses needle system UY 154 GAS Equivalent to 151x21, UY 154 GAS SES, UY 154 FGS, UYX15, CANU 06:60EB
Willcox & Gibbs Model# W-22 uses needle system UY 113 GS Equivalent to 2055, UOX113 GS, CANU 26:65
Willcox & Gibbs Model# WS All Classes use needle system UY 128 GAS Equivalent to 149X3, 1280, TVX3, CANU 38:00